원문 : http://www.ischo.net -- 조인상 // 시스템 엔지니어

Writer : http://www.ischo.net -- ischo // System Engineer in Replubic Of Korea

+++++++++++++++++++++++++++++++++++++++++++++++++++++++

 

원문 : http://www.ischo.net -- 조인상 //시스템 엔지니어

+++++++++++++++++++++++++++++++++++++++++++++++++++++++




어플리케이션 설치 확인

# esxcli software vib list | grep Hewlett-Packard

hpssacli                       1.60.17.0-5.5.0.1198610                Hewlett-Packard  PartnerSupported  2014-07-10



HP SSACLI 설치

  - HP site 에서 HP Proliant Smart Array Controller Driver for VMware ESXi  를 다운로드 받아 아래의 커맨드로 설치한다.

 # esxicli software vib install -v /tmp/다운받은파일명.vib



커맨드 예제


* 어플리케이션 위치 /opt/hp/hpssacli/bin


Show configuration
# hpssacli ctrl all show config


Controller status
# hpssacli ctrl all show status


Show detailed controller information for all controllers
# hpssacli ctrl all show detail


Show detailed controller information for controller in slot 0
# hpssacli ctrl slot=0 show detail


Rescan for New Devices
# hpssacli rescan


Physical disk status
# hpssacli ctrl slot=0 pd all show status


Show detailed physical disk information
# hpssacli ctrl slot=0 pd all show detail


Logical disk status
# hpssacli ctrl slot=0 ld all show status


View Detailed Logical Drive Status
# hpssacli ctrl slot=0 ld 2 show


Create New RAID 0 Logical Drive
# hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0


Create New RAID 1 Logical Drive
# hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1


Create New RAID 5 Logical Drive
# hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5


Delete Logical Drive
# hpssacli ctrl slot=0 ld 2 delete


Add New Physical Drive to Logical Volume
# hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7


Add Spare Disks
# hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7


Enable Drive Write Cache
# hpssacli ctrl slot=0 modify dwc=enable


Disable Drive Write Cache
# hpssacli ctrl slot=0 modify dwc=disable


Erase Physical Drive
# hpssacli ctrl slot=0 pd 2I:1:6 modify erase


Turn on Blink Physical Disk LED
# hpssacli ctrl slot=0 ld 2 modify led=on


Turn off Blink Physical Disk LED
# hpssacli ctrl slot=0 ld 2 modify led=off


Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)
# hpssacli ctrl slot=0 modify cacheratio=100/0


Enable smart array write cache when no battery is present (No-Battery Write Cache option)
# hpssacli ctrl slot=0 modify nbwc=enable


Disable smart array cache for certain Logical Volume
# hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable


Enable smart array cache for certain Logical Volume
# hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable


Enable SSD Smart Path
# hpssacli ctrl slot=0 array a modify ssdsmartpath=enable


Disable SSD Smart Path
# hpssacli ctrl slot=0 array a modify ssdsmartpath=disable