Vmware ESXI 환경에서 HP Smart Array CLI 사용하기 - command 예제
2015.07.29 22:02
원문 : http://www.ischo.net -- 조인상 // 시스템 엔지니어
Writer : http://www.ischo.net -- ischo // System Engineer in Replubic Of Korea
+++++++++++++++++++++++++++++++++++++++++++++++++++++++
원문 : http://www.ischo.net -- 조인상 //시스템 엔지니어
+++++++++++++++++++++++++++++++++++++++++++++++++++++++
어플리케이션 설치 확인
# esxcli software vib list | grep Hewlett-Packard
hpssacli 1.60.17.0-5.5.0.1198610 Hewlett-Packard PartnerSupported 2014-07-10
HP SSACLI 설치
- HP site 에서 HP Proliant Smart Array Controller Driver for VMware ESXi 를 다운로드 받아 아래의 커맨드로 설치한다.
# esxicli software vib install -v /tmp/다운받은파일명.vib
커맨드 예제
* 어플리케이션 위치 /opt/hp/hpssacli/bin
Show configuration
# hpssacli ctrl all show config
Controller status
# hpssacli ctrl all show status
Show detailed controller information for all controllers
# hpssacli ctrl all show detail
Show detailed controller information for controller in slot 0
# hpssacli ctrl slot=0 show detail
Rescan for New Devices
# hpssacli rescan
Physical disk status
# hpssacli ctrl slot=0 pd all show status
Show detailed physical disk information
# hpssacli ctrl slot=0 pd all show detail
Logical disk status
# hpssacli ctrl slot=0 ld all show status
View Detailed Logical Drive Status
# hpssacli ctrl slot=0 ld 2 show
Create New RAID 0 Logical Drive
# hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0
Create New RAID 1 Logical Drive
# hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1
Create New RAID 5 Logical Drive
# hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5
Delete Logical Drive
# hpssacli ctrl slot=0 ld 2 delete
Add New Physical Drive to Logical Volume
# hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7
Add Spare Disks
# hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7
Enable Drive Write Cache
# hpssacli ctrl slot=0 modify dwc=enable
Disable Drive Write Cache
# hpssacli ctrl slot=0 modify dwc=disable
Erase Physical Drive
# hpssacli ctrl slot=0 pd 2I:1:6 modify erase
Turn on Blink Physical Disk LED
# hpssacli ctrl slot=0 ld 2 modify led=on
Turn off Blink Physical Disk LED
# hpssacli ctrl slot=0 ld 2 modify led=off
Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)
# hpssacli ctrl slot=0 modify cacheratio=100/0
Enable smart array write cache when no battery is present (No-Battery Write Cache option)
# hpssacli ctrl slot=0 modify nbwc=enable
Disable smart array cache for certain Logical Volume
# hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable
Enable smart array cache for certain Logical Volume
# hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable
Enable SSD Smart Path
# hpssacli ctrl slot=0 array a modify ssdsmartpath=enable
Disable SSD Smart Path
# hpssacli ctrl slot=0 array a modify ssdsmartpath=disable
댓글 0
번호 | 제목 | 글쓴이 | 날짜 | 조회 수 |
---|---|---|---|---|
10 | HP-UX 11i v3 - Native Multi-Pathing for Mass Storage | 조인상 | 2011.10.28 | 11096 |
9 | Dynamic Root Disk A.3.9.* Administrator's Guide | 조인상 | 2011.10.28 | 11076 |
8 | HP-UX 11.11 에서 cpu/mem/Kernel info 긁어오는 스크립트 | 조인상 | 2011.06.24 | 10762 |
7 | HP-UX 11i v3 소개 및 release note + Road Map | 조인상 | 2011.10.28 | 10574 |
6 | bdf의 결과를 GB단위로 보여주는 스크립트 [1] | 조인상 | 2015.10.27 | 10057 |
» | Vmware ESXI 환경에서 HP Smart Array CLI 사용하기 - command 예제 | 조인상 | 2015.07.29 | 9206 |
4 | 파트너 관련 각 시험 코드표 | 조인상 | 2011.06.15 | 8685 |
3 | VG00 의 mirror 상태 점검 스크립트 | 조인상 | 2015.06.12 | 5788 |
2 | HP rx2660서버에서 H/W RAID 구성하기 | ischo | 2019.10.04 | 2355 |
1 | 특정계정만 ssh 접속 불가 sftp 만 접속 가능한 환경 만들기 | ischo | 2019.05.09 | 2285 |