# esxcli software vib list | grep Hewlett-Packard
hpssacli 1.60.17.0-5.5.0.1198610 Hewlett-Packard PartnerSupported 2014-07-10
HP SSACLI 설치
- HP site 에서 HP Proliant Smart Array Controller Driver for VMware ESXi 를 다운로드 받아 아래의 커맨드로 설치한다.
# esxicli software vib install -v /tmp/다운받은파일명.vib
커맨드 예제
* 어플리케이션 위치 /opt/hp/hpssacli/bin
Show configuration
# hpssacli ctrl all show config
Controller status
# hpssacli ctrl all show status
Show detailed controller information for all controllers
# hpssacli ctrl all show detail
Show detailed controller information for controller in slot 0
# hpssacli ctrl slot=0 show detail
Rescan for New Devices
# hpssacli rescan
Physical disk status
# hpssacli ctrl slot=0 pd all show status
Show detailed physical disk information
# hpssacli ctrl slot=0 pd all show detail
Logical disk status
# hpssacli ctrl slot=0 ld all show status
View Detailed Logical Drive Status
# hpssacli ctrl slot=0 ld 2 show
Create New RAID 0 Logical Drive
# hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0
Create New RAID 1 Logical Drive
# hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1
Create New RAID 5 Logical Drive
# hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5
Delete Logical Drive
# hpssacli ctrl slot=0 ld 2 delete
Add New Physical Drive to Logical Volume
# hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7
Add Spare Disks
# hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7
Enable Drive Write Cache
# hpssacli ctrl slot=0 modify dwc=enable
Disable Drive Write Cache
# hpssacli ctrl slot=0 modify dwc=disable
Erase Physical Drive
# hpssacli ctrl slot=0 pd 2I:1:6 modify erase
Turn on Blink Physical Disk LED
# hpssacli ctrl slot=0 ld 2 modify led=on
Turn off Blink Physical Disk LED
# hpssacli ctrl slot=0 ld 2 modify led=off
Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)
# hpssacli ctrl slot=0 modify cacheratio=100/0
Enable smart array write cache when no battery is present (No-Battery Write Cache option)
# hpssacli ctrl slot=0 modify nbwc=enable
Disable smart array cache for certain Logical Volume
# hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable
Enable smart array cache for certain Logical Volume
# hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable
Enable SSD Smart Path
# hpssacli ctrl slot=0 array a modify ssdsmartpath=enable
Disable SSD Smart Path
# hpssacli ctrl slot=0 array a modify ssdsmartpath=disable
댓글 0
번호 | 제목 | 글쓴이 | 날짜 | 조회 수 |
---|---|---|---|---|
10 | 장비 H/W미러링 장치 확인 및 미러상태 점검 [1] | 조인상 | 2013.02.25 | 27045 |
9 | HP-UX Kernel Tuning and Performance Guide - 2000.3.15 | 조인상 | 2011.08.30 | 27211 |
8 | ignite를 이용한 OS백업 | 조인상 | 2011.07.21 | 28567 |
7 | NTP 서버/클라이언트 설정 | 조인상 | 2011.03.01 | 29624 |
6 | 해당 포트를 열고 있는 프로세스 확인방법. netstat, lsof | 조인상 | 2012.09.20 | 33524 |
5 | swinstall 로 depot 설치하기 | 조인상 | 2011.03.29 | 36103 |
4 | HP-UX 네트웍 관리 | 조인상 | 2011.03.08 | 36312 |
3 | disk 추가에서 볼륨생성까지 | 조인상 | 2011.02.18 | 40289 |
2 | HP-UX 기본 점검 명령어 | 조인상 | 2011.02.22 | 42025 |
1 | HP-UX 장비 GSP/MP접속 및 기본 사용법 [2] | 조인상 | 2011.02.25 | 56461 |