원문 : http://www.ischo.net -- 조인상 // 시스템 엔지니어
Writer : http://www.ischo.net -- ischo // System Engineer in Replubic Of Korea
+++++++++++++++++++++++++++++++++++++++++++++++++++++++
원문 : http://www.ischo.net -- 조인상 //시스템 엔지니어
+++++++++++++++++++++++++++++++++++++++++++++++++++++++
Version mismatch error due to incorrect CommonIO bundle on 0806 OE media
The SerialSCSI-00 B.11.23.0806 bundle depends on CommonIO B.11.23.0803 or later. An
incorrect version of CommonIO is included on the 0806 OE media.
If you install SerialSCSI-00 B.11.23.0806 without CommonIO B.11.23.0803 or later, the sasmgr
get_info command returns an error. For example:
# sasmgr get_info -D /dev/sasd0
Driver specific and common library version mismatch. Exiting..
Corrective Action: Install CommonIO B.11.23.0803 from the AR 0806 release media. You
can also download CommonIO B.11.23.0803 or later from the Software Depot website:
http://software.hp.com
Search for CommonIO. In the search results, click Receive For Free in the “HP-UX Common
Bundle” row.